FAM 15/30 ATEX
Performing maintenance / inspection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 73 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Testing the level sensor of the vacuum chamber
You will require:
Philips screwdriver PH#2 + PH#3
Fork wrench SW13
Performance instructions:
Remove 4 nuts from the cover of the vacuum
chamber
Undo the safety screw of the level sensor plug.
Pull out the plug
Carefully remove the cover together with the
level sensor
Hang the cover to the vacuum chamber as
shown in the accompanying illustration.
Check the level sensor for dirt and clean as
needed.
Check the functioning of the float level sensor
on the basis of the SPS inlets. Move the float
away by hand.
The main switch of the FAM must be set to
"ON" position while doing so.
See the illustration below in this connection.