FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 50 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
[H11] Float switch
Step
DESCRIPTION
Malfunction:
"Float switch"
1.
Empty oil pan
2.
Press RESET key
3. Start
FAM
4.
Carry out leakage check, remedy leakages
5.
Malfunction reappears after ~ 2 seconds?
->a. Yes
-> proceed to Step 7.
6.
->b. No
-> proceed to Step 8.
7.
Check float switch and supply lines
8.
The failure is repaired.