FAM 15/30 ATEX
Performing maintenance / inspection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 76 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Replacing the filter element on the oil mist separator
Quit Automatic mode on the FAM. Afterwards, wait
approximately 1 minute, until normal pressure (ambient
pressure) has been established in the vacuum chamber.
Rotate the separator pot [2] 1/8th of a turn to the left
(bayonet seal) and remove from the bottom.
Turn the used filter element clockwise to remove and
dispose of it in an environmentally correct manner.
Insert the new filter element and screw it into the separator
head (1) by turning it counterclockwise.
Insert the separator pot (2) into the separator head (1), and
secure it with a 1/8th turn (bayonet seal).
The filter element change is now complete.