FAM 15/30 ATEX
Starting up the FAM
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 39 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Starting up the FAM
After all connections are made and the preparations for commissioning are
complete, switch on the FAM at the main switch. For the lamp test, all lamps light up
briefly.
Then the FAM goes to malfunction "[H15] V-pump pressure"; the malfunction light
[S3] "Malfunction" blinks. This fault message results from the switch position of the
"Siguard" (electric circuit diagram = A5) in the control cabinet and is eliminated by
pressing the button [S1] "Start delay" or the button [S3] "Malfunction".
The system now begins with the starting phase. The vacuum pump starts up, the
inlet valve opens, and the vacuum chamber is filled. When the vacuum chamber is
filled to filling level [02], the evacuation pump is started up and the starting phase is
finished. The purification operation runs. This is shown by the lighting up of the
operating status lamp "FAM operation (H4)".
Setting the vacuum pressure
Now regulate the vacuum pressure in the vacuum chamber with the throttle valve
underneath the vacuum pressure display, depending on the operating viscosity.
Oil
Operating viscosity Pressure setting (absolute pressure)
Hydraulic oil
50 mm²/s
250 mbar / 25 kPa
Lubricant
300 mm²/s
250 - 500 mbar / 52 - 50 kPa
(depending on foaming behavior)