[H8] V-pump temperature
Step
DESCRIPTION
1. Malfunction:
"V-pump temperature"
Cause:
Oil temperature in the vacuum chamber too high
2.
Check the oil level in the vacuum chamber; if necessary, top off with oil
3.
To reset the failure, press the RESET key
4.
Does the malfunction recur after the vacuum pump has started?
->a. Yes
-> proceed to Step 6.
5.
->b. No
-> proceed to Step 9.
6.
Vacuum pump or controller in the control cabinet defective.
7.
Repair or replace vacuum pump / exchange parts of the controller.
8.
Check the pressure relief valve of the evacuation pump for proper
functioning.
9.
The failure is repaired.