Performing maintenance
Calibrate the volume flow meter
Check the function of the volume meter yearly by means of measured flow.
Measured flow of the volume meter is done as follows:
1. Detach a hose A / B / C at the CTM-E
module.
2. In the user interface, select the detached
hose as the outlet.
3. Select the volume of 5 liters and a flow
rate of 5 l/min via the user interface.
3. Make sure there is a suitable measuring
vessel available.
Insert the hose into the measuring
vessel.
Hold onto the hose while
draining the unit.
4. Start the process on the user interface.
5. Once the selected rinsing volume has
been reached on the monitor, or once no
more test liquid comes out of the spray
gun, read off the amount of liquid issued
on the measuring vessel scale.
A tolerance of +/- 5% is acceptable.
If the deviation is greater, the meter has
to be sent in to HYDAC Customer
Service for adjustment.
6. The calibration of the volume flow
counter is completed.