
HMG 3010
Page 78
Edition 2013-03-26 - V04 R01
Part No.: 669855
6.6 Technical data
Sensor inputs
The HMG features:
•
4 sensor input jacks (channel A – H) for up to 8 analogue sensors,
or up to 4 SMART sensors and
•
1 input jack with 2 digital inputs (channel I - J) and
a voltage input of -10 V to + 10 V (shown at channel H)
The sensors are connected using an standard M12x1 male connector (5 pole).
Channel A to H:
•
Automatic detection for HSI sensors (pressure, temperature, flow rate trans-
mitters and SMART sensors)
•
Connection of commonly-available sensors with current or voltage signals
•
Differential channels for channel A - B; channel C - D; Differential channel for
flow rate measurement orifice (shown at channel B)
Channel I and J:
•
Frequency channels (speed (rpm) measurement, counting function)
Frequency range: 1 .. 30,000 Hz
(
≤
± 0.1% FS max.)
Switching threshold / switch-back threshold: 2V/1V
Max. input voltage: 50 V; display delay
max. 2 s
.
Overview of signals / measurement inputs
Measurement
range
(accuracy)
Chann
.
A
Chann
.
B
Chann
.
C
Chann
.
D
Chann
.
E
Chann
.
F
Chann
.
G
Chann
.
H
HIS
(
≤
±
0.1 % FS max.)
X
X
X
X
X
X
X
X
4 .. 20 mA
(
≤
±
0.1 % FS max.)
X
X
X
X
X
X
X
X
0 .. 20 mA
(
≤
±
0.1 % FS max.)
X
X
X
X
X
X
X
X
0 .. 4.5 V
(
≤
±
0.1 % FS max.)
X
X
X
X
X
X
X
X
0 .. 5 V
(
≤
±
0.2 % FS max.)
X
X
X
X
X
X
(
≤
±
1.0 % FS max.)
X
X
0 .. 10 V
(
≤
±
0.1 % FS max.)
X
X
X
X
X
X
(
≤
±
0.5 % FS max.)
X
X
0 .. 50 V
(
≤
±
0.1 % FS max.)
X
X
0.5 .. 4.5 V
(
≤
±
0.1 % FS max.)
X
X
X
X
x
x
x
x
0.5 .. 5.5 V
(
≤
±
0.2 % FS max.)
X
X
X
X
X
X
(
≤
±
1.0 % FS max.)
X
X
1 .. 5 V
(
≤
±
0.2 % FS max.)
X
X
X
X
X
X
(
≤
±
1.0 % FS max.)
X
X
1 .. 6 V
(
≤
±
0.2 % FS max.)
X
X
X
X
X
X
(
≤
±
1.0 % FS max.)
X
X
-10 .. +10 V
(
≤
±
0.5 % FS max.)
X