4
hunter.direct/ICC2help
Specifications
Specifications
OPERATING SPECIFICATIONS
• Number of Stations:
Modular design expandable from
8 to 38 (plastic), 8 to 54 (metal)
• Station Run Time:
1 minute up to 12 hours
• Start Times:
8 per program, 4 independent
programs (A, B, C, and D)
• Simultaneous Program Operation:
2
• Sensor Inputs:
1
• Pump/Master Valve Outputs:
1
• Watering Schedule:
7-day calendar, interval watering up
to a 31-day interval or true odd or even day programming
DIMENSIONS
PLASTIC CABINET
•
Height: 12" (30.5 cm)
•
Width: 13.7" (34.8 cm)
•
Depth: 5" (12.7 cm)
METAL CABINET (GRAY OR SS)
•
Height: 16" (40.6 cm)
•
Width: 13" (33 cm)
•
Depth: 5" (12.7 cm)
METAL PEDESTAL (GRAY OR SS)
•
Height: 36" (91.4 cm)
•
Width: 11.5" (29.2 cm)
•
Depth: 5" (12.7 cm)
PLASTIC PEDESTAL
•
Height: 39" (99.1 cm)
•
Width: 24" (61 cm)
•
Depth: 17" (43.2 cm)
ELECTRICAL SPECIFICATIONS
• Transformer Input:
120 VAC, 60 Hz
(230 VAC, 50/60 Hz international use)
• Transformer Output:
24 VAC, 1.4 A
• Station Output:
24 VAC, up to 0.56 A
• Pump/Master Valve Output:
24 VAC, up to 0.56 A
• Battery:
9-volt alkaline battery (not included) used only
for non-AC programming; non-volatile memory maintains
program information
• Front Panel Battery:
Internal CR2032 lithium (included)
for real-time clock
APPROVALS
•
CE, UL, cUL, FCC, RCM
• Plastic Cabinet:
IP44, NEMA 3R
• Metal Cabinet (Gray or SS):
IP44, NEMA 3R
• Metal Pedestal (Gray or SS):
IP44, NEMA 3R
• Plastic Pedestal:
IP24, NEMA 3R
DEFAULT SETTINGS
•
All stations are set to zero run time. This controller has a
non-volatile memory that retains all entered program data
even during power outages, without the need for a battery.