30
hunter.direct/ICC2help
DELAY BETWEEN STATIONS
This feature allows the user to program a delay between
station activation and shutoff. This is particularly helpful on
systems with slow-closing valves, pumps that are operating
near maximum flow, and/or alternate water sources with
slower recovery such as wells and water storage tanks.
1.
With the dial in the Run position, press and hold the –
button, turn the dial to the Run Times position, and
release the – button.
2.
The display will show a delay time in seconds, which is
default set to 00 seconds. Press the + and – buttons to
increase or decrease the delay times. For any delay time
less than 1 minute, the display will show only seconds (e.g.,
SEC 45). Once you program over 59 seconds, “SEC” will
change to “Hr” and the delay time converts into minutes
and hour mode (e.g., Hr 0:30 represents 30 minutes, Hr
2:00 represents 2 hours).
3.
The Delay Between Stations feature applies to all stations,
and can be programmed from 1 second up to 10 hours.
4.
Rotate the dial back to the Run position when finished
programming all Delays Between Stations.
Note: The Master Valve/Pump Start circuit will remain
active during the first 15 seconds of any programmed Delay
Between Stations to aid in the closing of the valve and to avoid
unnecessary cycling of the pump.
HIDE PROGRAMS
ICC2 is factory configured with 4 independent programs (A,
B, C, and D) that are utilized when watering multiple different
landscapes and plant-type requirements. The controller can
be customized to display only the most basic programming,
and thus, hide extra programs.
1.
With the dial in the Run position, press and hold the –
button, turn the dial to the Water Days position, and
release the – button.
2.
Use the + and – buttons to change between either 4 or 1.
The default setting is set to 4, which shows all 4 programs
available, and all 8 start times available. Switching to a
setting of 1 will show only program A and only 1 start time
available.
3.
Rotate the dial back to the Run position when finished
programming all Hide Programs.
Hidden and Advanced Features
SOLAR SYNC DELAY
ICC2 with built-in Solar Sync programming has the ability to
delay the automatic, daily update of the Seasonal Adjustment
value from Solar Sync for up to 99 days. This option may be
advantageous to users who do not want the program run
times to be adjusted by Solar Sync for a specific period of time
(e.g., during an overseeding or overwatering schedule). This
function allows the controller to operate with a manually set,
fixed Seasonal Adjustment value, at least until the Solar Sync
Delay period expires. However, even while Solar Sync Delay is
active, the Solar Sync sensor will continue to gather weather
information and calculate the Seasonal Adjust Value; it just
won’t be applied to the run times. Once the Solar Sync Delay
ends, the updated Seasonal Adjust value will be applied.
Note: Solar Sync Delay feature is only accessible when a Solar
Sync sensor is installed.
4.
With the dial in the Run position, press and hold the +
button, turn the dial to the Solar Sync position, and release
the + button.
5.
The display will show “d:00,” where “d” indicates days and
“00” indicates the number of days to be delayed.
6.
Press the + or – buttons to increase or decrease the
number of Solar Sync Delay days you desire. Once the
correct number of days is displayed, return the dial to the
Run position.
Note: The number of days remaining will not be displayed on
the Run screen. To check if the Solar Sync Delay feature is
active, open the Solar Sync Delay menu and check the number
of days shown. If 1 or more days are programmed, then Solar
Sync Delay is active, but if 0 days are programmed, then Solar
Sync Delay is disabled.