Alarm Log, “Reason” Labels
The Reason label indicates the type of alarm condition.
Unknown
No reason specified
Overflow
Overflow alarm occurred
Underflow
Underflow alarm occurred
Overcurrent
Station Overloaded
Activated
Sensor Activated
Deactivated
Sensor Deactivated
Damaged
Decoder is damaged (continuous low
voltage output)
Comm Fail
Decoder communications failure - no
response
Unavailable
Cannot run station due to too many
stations already running
Comm Restore
Communications was restored to a
decoder
Config Fail
Failure occurred when attempting to
configure a sensor decoder on the
2-wire path
Flow Totals
Failure occurred when attempting
to get the flow totals from a sensor
decoder
Flow Detail
Failure occurred when attempting to
get the flow detail data from a sensor
decoder
Sensor Alarm
The status of the Sensor Decoder
Alarm Polling has changed
Lith Fail
The lithium battery in the facepack
has failed
Clock Fail
A problem exists with the Real Time
Clock (RTC) in the facepack
COntrOller lOGS
Track significant events at the controller, which are not
necessarily alarms or malfunctions.
Message
Description
EASY RETRIEVE
RESTORED
Easy retrieve programs
were restored
PROGRAM X RESET BY
CENTRAL
Field controller Program X
was reset by central
OFF MODE SET AT
CONTROLLER
Dial was put in OFF
position
RUN MODE SET AT
CONTROLLER
Dial was taken out of OFF
position
PROGRAMMABLE OFF SET
AT CONTROLLER
Programmable Off was
initiated at the controller
PAUSE MODE SET AT
CONTROLLER
Pause Mode was initiated
at the controller
PAUSE MODE CANCELLED
AT CONTROLLER
Pause Mode was cancelled
at the controller
PROGAMMABLE OFF SET
BY CENTRAL
Programmable Off was
initiated by central
PAUSE MODE SET BY
CENTRAL
Pause Mode was initiated
by central
PAUSE MODE CANCELLED
BY CENTRAL
Pause Mode was cancelled
by central
SUSPEND MODE SET BY
CENTRAL
Suspend Mode was
initiated by central
SUSPEND MODE
CANCELLED BY CENTRAL
Suspend Mode was
cancelled by central
PROGRAMMABLE OFF
TIMEOUT
Programmable Off timed
out
PAUSE TIMEOUT
Pause timed out
NO WATER WINDOW
VIOLATION
A No Water Window
Violation occurred
MEMORY CORRUPTED
RESET TO DEFAULTS
Memory is suspect and
was reset to defaults by
microcontroller
ALL DATA RESET TO
DEFAULTS
All data was reset in the
controller
ALL LOGS RESET AT
CONTROLLER
All logs were reset at the
controller
FLOW TOTALS RESET AT
CONTROLLER
All flow totals were reset at
the controller
ALL PROGRAM DATA
RESET AT CONTROLLER
All programs were reset at
the controller
ALL NAMES RESET AT
CONTROLLER
All names were reset at the
controller
IRRIGATION STOPPED BY
CENTRAL
Irrigation was stopped by
the central