21
CAUTION: Understand your irrigation system’s hydraulic
restrictions before allowing programs to overlap.
Overlapping programs may overdrive the hydraulics of
your system. Overdriving your hydraulics will damage the
components and result in inferior sprinkler performance.
More advanced programming overlap options are available
by turning the dial to the SET PROGRAM OVERLAP
OPTIONS dial position.
Normally, the cursor will be positioned at the first Start
Time hour position when turning the dial to the Set
Program Start Time position.
• To change the Stack/Overlap settings for the Program,
use the arrow key to navigate up to the Stack/Overlap
indication.
• Use + or – to change between Stack and Overlap.
• Use the arrow keys to move back down to the Start
Times if necessary.
Multiple Start Times
To set Start Times for the Program, move to the Start Time
number, and use the + or – buttons to set the hour, then
minutes, and then AM/PM settings unless using 24-hour
option.
• If a Start Time is skipped (for example, a time is set
for 1, 2 is left at OFF, and a time is set for 3), the Start
Time will be accepted, but when returning to this
dial position, the Start Times will be moved to a
sequential order (the Start Time set for 3 will have
been moved to 2). This is by design.
• If an earlier Start Time is set for a higher-numbered
Start (for example, Start 1 is set to 4:00 AM, and
Start 2 is set to 3:00 AM), when returning to this dial
position the Start Times will have been reorganized
in chronological order. The lowest numbered Start
Time will always have the earliest time of day (in the
example, Start 1 will be at 3:00 AM and Start 2 will be
at 4:00 AM).
Press the Information button while in the Set Watering
Start Times position to show a summary of all Start Time
information for the selected Program. This will show total
station run time per start, number of starts, and total time
for the program.
No-Water Window
Programming this feature is explained in the Extended
Features section.
SettInG StAtIOn run tIMe DurAtIOn
Three items are programmed at this position:
• Station watering duration
• Seasonal Adjust value for the Program
• Hidden Feature: Timed Delay between Stations
1. Turn the dial to the SET STATION RUN TIMES position.
2. Select the Program (A – F) by pressing the Program
button
3. Press the + or – button to change the value of the
flashing cursor. The cursor initially appears in the
minutes field.
4. Press the right and left arrow buttons to change
from minutes to hours or seconds cursor positions.
Set the run time in h:mm:ss format.
5. Run times may be from 1 second to 6 hours, or any
increment in between.
6. Press the up and down arrow buttons to change to a
different station number
7. The copy and paste buttons may be used to speed up
programming.
Содержание ACC-1200