6 Diagnostic messages
DDLM_SLAVE_DIAG mode allows the master to access diagnostic data from the module. The
number of Octets is 57, with the exception of reduced diagnostics, in which the number of diag-
nostic bits is restricted to 16.
The following is a list of diagnostic messages supported by the Hübner absolute encoder / bus
modules. Diagnostic data is output according to the specifications for Profibus® PROFILE FOR
ENCODERS, PNO order no. 3.062.
Octet
Parameter
Bit no.
Class
1-3
Station sta-
tus
(see Profi-
bus stand-
ard)
1
4
Diagnostic
Master Add
1
5-6
PNO
–
number
15 - 0
PNO number of
the encoder
1
7
Expanded
diagnostic
header
Number of diag-
nostic bytes
1
8
Alarm mes-
sage
4
EEProm memory
error
1 = error
1
9
Operating
status
0
1
2
3
Direction
Class 2 function
Diagnostic routine
Scaling function
0 = CW, 1 = CCW
0 = Off, 1 = On
0 = Off, 1 = On
0 = Off, 1 = On
1
10
Encoder
type
1
Single/Multiturn
Singleturn = 0
Multiturn = 1
1
11-14
Resolution /
revolutions
(hardware)
0
– 23
Singleturn resolu-
tion
4096 (1000 H)
1
15-16
0
– 23
Multiturn resolu-
tion
4096 (1000 H)
1
20-21
Warning
messages
20/4
Operating time
warning after 10
5
hours
0 = no, 1 = yes
2
24-25
Profile ver-
sion
15
– 8
7 - 0
Revision no.
Index
2
26-27
Software
version
15
– 8
7 - 0
Revision no.
Index
2
28-31
Operating
time
23 - 0
Incrementing
every 6 minutes
2