![Hubner U-ONE-LWL Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/hubner/u-one-lwl/u-one-lwl_operating-instructions-manual_2180881014.webp)
UO-EPB-1
Operating and configuration instructions
14
UO-EPB1_Manual-en_R1
If this is not observed, the module will detect a configuration error. This will be displayed in the
junction box cover. The red LED will be continuously illuminated, and the green one will flash.
NOTE!
To activate configuration of resolution per revolution, the class 2 function and the
scaling function must be switched on. The preset should then be reset in normal op-
eration, since it refers to the scaled values.
4.7 Configuration in hex code
The configuration can also be carried out in the HEX
– CONFIGURE window. However, this is
time consuming and requires a precise knowledge of the functions of the individual bits and
bytes.
4.8 Operating the module in the Hübner 2.1 and Hübner 2.2 profiles
These two profiles have some additional functions in addition to the standard profiles, the config-
uration of which is explained here based on COM Profibus®.
The scaling function must be switched on to operate the additional functions.
Octet