UO-EPB-1
Operating and configuration instructions
22
UO-EPB1_Manual-en_R1
5.2.2 Set counting direction
The counting direction can be reversed in commissioning mode online using bit 28. The coder re-
turns the current direction after the changeover to the master. A 0 means the counting direction is
clockwise (looking toward the shaft) and 1 means anti-clockwise.
Status bits
Data bits
31
30
29
28
27
26 25
24
– 1
0
M->S
0
0
0
1
0
0
0
Bit 28 switches the direction of rotation from
0 to 1 and vice versa
S->M
0
0
0
0/1
0/1
0
1
Acknowledge the
new direction of
rotation in bit 0
1/0
M->S
0
0
0
0
0
0
0
End the changeover at bit 28 = 0
S->M
0
0
0
0/1
0/1
0
1
Continue process value output
M = Master, S = Slave
NOTE!
The preset value must be reset after setting the direction of rotation.
5.2.3 Scaling the module in the teach in process
This process makes it possible to automatically scale the module. After starting the process, the
system is moved along a defined path. Then after the process is stopped, the number of steps
into which the travelled path should be divided is input. The path of travel may not exceed 2047
revolutions.
5.2.3.1 Start scaling
Status bits
Data bits
31
30
29
28
27
26
25
24
– 1
M->S
0
1
0
0
0
0
0
Bit 30 = 1 = Start scaling
S->M
0
1
0
0/1 0/1
0
1
Acknowledge through Bit 30 = 1
M->S
0
0
0
0
0
0
0
Reset previous scaling
S->M
0
1
0
0/1 0/1
0
1
process value output with scaling factor 1
M = Master, S = Slave
After this function, the gear factor is set to 1 and the drift (preset) is deleted.
Now the system must be moved the defined path. The path of travel is displayed unscaled by
process value output.