UO-EPB-1
Operating and configuration instructions
10
UO-EPB1_Manual-en_R1
3.4 Type plate
The following image shows an example of a type plate.
The type plate is located on the outside
of the housing, and includes the following
information:
Manufacturer
Type, year of construction
CE mark
Serial number (S/N)
Protective class
ID number
Certification information
3.5 Electrical data
Information
Value
Supply voltage
Delivered to the SCU module via the module bus connector
Device temperature range
-
25°C…+ 60°C
Power consumption
< 3 W
Connection technology
Sub-D
Protective class in accord-
ance with DIN EN 60529
IP20 for cabinet installation
Degree of protection of cabinet:
≥ IP54
Elevation above sea level
≤ 3000 m
4 Commissioning
4.1 User manual
The module transmits the Multiturn and Singleturn absolute value for the basic device. It can be
configured in profiles CLASS 1 (Hübner 1.0) with configuration of the counting direction and
CLASS 2 (Hübner 2.0) with the additional setting for resolution / revolution and the overall resolu-
tion.
The profiles Hübner 2.1 and Hübner 2.2 are also available. These also provide the following func-
tions:
Expanded scaling function
Setting the counting direction, preset and automatic scaling (teach in) during online operation
in commissioning mode.
Limit switch function
Speed output
This function outsources part of the computing power from the Profibus® master to the function
module and relieves the load placed on the overall system. If these additional functions are not
required, however, then to simplify configuration it may make sense to use CLASS 1 or CLASS2
profiles.
Fig. 3-1: Type plate (example)