2
7. When working in closed place,
1) Operator should wear breathing mask.
2) Do not leave the unit working alone unattended.
3) Please note the maximum spraying quantity, do not excess the limit.
For indoor operation: If the concentrations of some special carriers which have been
dispersed as aerosols exceed certain amounts, could incur fire, so the dosage of these
combustible materials if used as fogging formulations should not exceed the following
maximum concentrations limit per 1,000.00 CBM.
a) Special carriers
b) Fuels or white oils
Nebal
3.0L
Vegetable Oil
2.5L
Glyzerine
2.5L
Diesel or Heating Oil
2.0L
Ekomist
2.0L
Kerosene
2.0L
Ethylengkole
2.0L
Petropal
2.0L
UK2-spezial
2.0L
Shell Risella
1.5L
VK1
1.5L
Nevolin or nevocol
1.5L
Note: The special carrier’s volume must be calculated accurately according to
room’s volume.
Set spraying solution output, could use water to measure solution output,
Nozzle diameter(mm)
0.8
1.0
1.2
1.4
1.6
2.0
Solution output (L/h)
10
15
20
30
35
42
Note: We have installed 1.2mm diameter nozzle to machine, put 1 pcs 0.8mm and
1pcs 1.6mm diameter nozzle into standard spare parts tool kits.
Because chemicals solution viscosity and environment condition, such as temperature,
pressure may influence solution output, so we recommend you to measure via your best
method.