S1700 Managed Series Ethernet Switches
Web User Manual
6 ACL Configuration
Issue 05 (2012-10-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
87
Table 6-5
Parameters of Standard IP Rule
Item
Description
ACL ID
ACL entry ID that the rules belongs to.
Rule ID
Enter an ID for rule and the range is 1~65535. If not specified, the
system, according to rule step, will distribute automatically.
Action
Specify switch to permit or deny data stream that matches to the rule.
Match IP Address
All Source IP: specify this rule to be applied to all IP data packages.
Specify Source IP /Mask: specify this rule to be applied to the IP data
package of specified IP /mask. The IP address will match the whole
field if no mask entered.
Time Range Name
Click Please Select button to specify effective time for the rule.
Step 3
Configure the needed parameter.
Step 4
Click Apply button to apply all the changes made.
----End
Create an Extending IP Rule
Step 1
Click ACL>ACL Profile.
Step 2
Click a created extending IP rule in the ACL list box, and click New button in list box of ACL
Rule to add a new rule, opening the configuration page shown as the figure below.
Figure 6-6
Create Extended IP Rule