Table 10-11
Parameters of Alarm
Item
Description
Entry
Number of alarm group entries.
Variable
Up to 32 characters, used to identify the MIB object groups.
Interval
The interval for monitoring the MIB object. Value ranges from
1-2147483647.
Sample Type
Delta: specify the changes of MIB within the specified interval of
alarm test.
Absolute: Test the actual MIB values.
Startup Alarm
Alarm state
Rising Threshold
Rising threshold generated by alarm events. Value ranges from 0 -
2147483647.
Rising Event Index
Specify the entries that defined in the event group.
Falling Threshold
Falling threshold generated by alarm events. Value ranges from 0 -
2147483647.
Falling Event Index
Specify the entries defined in the event group.
Owner
Create the user name of alarm group.
Create a RMON Alarm Group
Step 1
Click Network>RMON.
Step 2
Click Alarm in Tab, and click New to add an alarm group, the configuration page is displayed
as follows.
Figure 10-21
Create an Alarm Group
Step 3
Enter the related information about the alarm in the page.