S1700 Managed Series Ethernet Switches
Web User Manual
4 Interface Management
Issue 05 (2012-10-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
28
CAUTION
Interface auto-negotiation function must be disabled when user configures an interface
working in specified speed/duplex mode.
When auto-negotiation function is used, optimal configuration will be performed to link
among interfaces according to capability of two ends.
Speed and duplex of Giga SFP interface are fixed as 1000full.
Table 4-2
Parameters of Basic Attributes Configuration
Item
Description
Interface Name
Display the Interface number.
Admin Status
Enable/Disable the interface.
Flow Control
Enable/Disable flow control function of interface.
Negotiation
Enable/Disable automatic negotiation of interface.
Duplex
Configure duplex mode of interface.
Speed
Configure operation speed of interface.
Input Rate Limit
Configure input speed limit of interface.
Output Rate Limit
Configure output speed limit of interface.
Jumbo Frame
Specify the size of Jumbo frame on interface.
Description
Enter the description about interface.
Step 3
Configure parameters of interface.
Step 4
After that, click Apply to apply all the changes made. Use Basic Attributes page to view
status of valid switch interface.
----End
4.1.2 Statistics on Interface
Click Interface Management > Ethernet Interface > Statistics on Interface page to view
statistics information for each interface; statistics on interface is accounted after device startup
completed, the refresh frequency is 1/SEC.