If the RUN Indicator...
Because...
Then...
Steady on
There is power input, but the
board is faulty.
Power off the power supply,
rectify the fault, and power on
the pRRU.
Steady off
There is no power input, or an
alarm is reported on the board.
Power off the power supply
and check the power input. If
no fault is found after the
pRRU is powered off, clear the
fault on the board, and power
on the pRRU.
On for 1s and off for 1s
The device works properly.
End this operation.
On for 0.125s and off for
0.125s
The software of the board is
loading.
Wait five minutes for the
software to be successfully
loaded. If the software is
loading five minutes later, shut
off the power supply. Check
whether the data configuration
file is correct. After the fault is
rectify, power on the pRRU
again.
----End
LampSite
Installation Guide
5 Installing a pRRU
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
89