NOTE
l
If the PGND cable is provided by the customer, a copper-core cable with a minimum cross-sectional
area of 6 mm
2
(0.009 in.
2
) or 10 AWG is recommended.
l
The OT terminals at both ends of the PGND cable are assembled at the site.
l
The M6 OT terminal has the default size. You can replace it with another OT terminal of the expected
size based on the site requirement.
NOTICE
l
Ensure proper grounding of the RHUB using a PGND cable.
l
When installing the PGND cable, tightly press the OT terminal in the correct direction, as
shown in
Figure 4-30
Correct direction of an OT terminal for the PGND cable
Procedure
Step 1
Route the PGND cable by referring to
4.4.1 Requirements for Cable Layout
Step 2
Use a torque screwdriver or Phillips screwdriver to secure the M4 OT terminal at one end of the
PGND cable to the ground screw on the RHUB panel with a torque of 1.4 N•m. If the OT terminal
is a one-hole OT terminal, connect it to the ground screw on the lower part of the RHUB panel,
as shown in
.
LampSite
Installation Guide
4 Installing an RHUB
Issue 02 (2014-05-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
34