Context
Do as follows on the NQA server (TCP server):
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa-server tcpconnect
ip-address
port-number
The TCP monitoring service is configured.
NOTE
Note that the IP address and port number monitored by the server should be consistent with those configured
on the client.
----End
6.12.3 Configuring the TCP Client
This part describes how to set TCP test parameters.
Context
Do as follows on the NQA client (TCP client):
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
nqa
test-instance
admin-name
test-name
An NQA test instance is created and the test instance view is displayed.
Step 3
Run:
test-type
tcp
The test type is set to TCP.
Step 4
Run:
destination-address
ipv4
ip-address
The destination IP address is configured.
Step 5
To configure the destination port number, run the
destination-port
port-number
command.
Step 6
(Optional) Perform the following as required to configure other parameters for the TCP test ( For
detailed parameter configurations, see the chapter
Configuring Universal NQA Test
):
Quidway S2700 Series Ethernet Switches
Configuration Guide - Network Management
6 NQA Configuration
Issue 01 (2011-07-15)