On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
0
错误
表 格 结 果 无 效
A-2
Command
Function
Classification
SET BTSCPPARA
Set BTS BCPM Chip Parameters
SET BTSE1CLKM
Set E1 Clock Mode
SET BTSGPSCLK
Set BTS GPS Clock Parameters
SET BTSINFO
Set BTS Basic Information
SET BTSMLTDRPLNK
Set BTS Trunk Configuration
SET BTSSECTORPARA Set BTS Cell Parameters
SET BTSTERSIGLNK
Set BTS Terrestrial Signaling Link
STR BTS
Start BTS
Configuration
command
BLK BTSBCPM
Block BTS BCPM
BLK BTSCELL
Block BTS Cell
DEL HISALM
Delete BTS History Alarm
DSP
BTSBRDSPECSTAT
Display BTS Board Specific Status
DSP BTSBRDSTAT
Display BTS Board Status
DSP BTSBRDVER
Display BTS Board Version
DSP BTSENEVPARA
Display BTS Environment
Temperature/Humidity
DSP BTSFRMSTAT
Display BTS Baseband Subrack Status
DSP BTSPOWERPARA
Display BTS Power Supply Module
Parameters
DSP BTSWARNTHD
Display Alarm Thresholds
LST CURALM
List BTS Current Alarm
LST HISALM
List BTS History Alarm
RST BTSBRD
Reset BTS Board
RST BTSENVBOX
Reset Environment Alarm Box
SET BTSENEVPORT
Set Port Status of Monitor
SET BTSPOWEROFF
Shut Off BTS Power
SET BTSWARNTHD
Set BTS Alarm Threshold
STP BTSE1TST
Stop BTS E1 Test
STP BTSRESTRC
Stop BTS Resource Tracing
STR BTSE1TST
Start BTS E1 Test
STR BTSLPBACKTST
Start BTS Board Loopback Test
STR BTSRESTRC
Start BTS Resource Tracing
STR BTSSELFTST
Start BTS Board Self Test
STR E1MATCHTST
Start BTS E1 Connection Test
UBL BTSBCPM
Unblock BTS BCPM
UBL BTSCELL
Unblock BTS Cell
Maintenance
command
HELP
cBTS3612 MML Command Online Help
Help command