On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
Chapter 3 Component Failure
Handling
3-25
3.10
Power Supply Unit (PSU)
3.10.1 Fault Description
I.
The power module is not working or not working properly
II.
The power module fan is not running properly
III.
The voltage of the power output of the power module is
too high
IV.
The voltage of the power input of the power module is
too low
V.
The power module is over-heated
3.10.2 Troubleshooting
I.
The power module is not working or not working properly
When the three indicators on the panel of the power module are
all flashing or all gone off, it indicates the power module is not
working properly and there is an unexpected internal problem, the
module needs to be replaced.
II.
The power module fan is not running properly
When there is problem with the power module fan, the relevant
alarm indicator on the module panel will be on and the fan failure will
be reported. Replace the fan of the power module.