On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
Chapter 2 General Fault
Processing
2-16
require the OMC to configure the relevant local BOOTP information.
This set of BOOTP information should be unique and in conformity
with the data configuration in the BSC.
If the OMC has set up incorrect BOOTP information, the MAC
field in the BOOTP request package will not match the BOOTP
information, which will result in the BOOTP request failure and OML
establishment failure.
Solution: Query the BOOTP information of the BTS in the OMC,
and compare it with the data configuration in the BSC, change those
data that do not match.
VI.
Remote OMC failure
The remote OMC plays a role of BOOTP Server and TCP
Server during the establishment of OML. Therefore, the remote OMC
failure will result in OML failure. The possible OMC failure includes:
1) BAM system collapse or BAM process not started. In such
case, BAM process or BAM system must be restarted.
2) The loading process of BAM appears abnormal -- you may
need to restart the BAM loading process.
3) BAM bottom-layer communication process (Exchange Server)
appears abnormal -- you may need to restart the BAM bottom-layer
communication process.