On-site Maintenance Manual
Airbridge cBTS3612 CDMA Base Station
Chapter 4 Component
Replacement
4-16
thus, can be handled flexibly), we should also pay attention to the
following:
I.
The influence on the service
Replacing a RLDU may affect the services transmitted through it.
Remember to switch off the RLDU from the BTS switch box before
replacing it.
II.
Handling relevant cables
Before replacing the RLDU, disconnect the power cables and
data cables on the panel. Connect them back properly after the
RLDU is installed
III.
Installing RLDU
When installing the RLDU, make sure its panel is in a seamless
contact with the front edge of the subrack and then tighten the
screws, or the RF transmission may not be able to meet the index.
IV.
Setting the switches
After installing the new RLDU, the S/W switch setting should be
the same as that of the replaced unit.
4.2.12 Duplexer Unit (CDU, DFU, DDU)
cBTS3612 supports 3 types of duplexers Unit, including
CDU,DFU, DDU. Their replacement procedures are quite similar.
For example, the replacement procedures of CDU will be
introduced.