NOTE
When the power indicator is steady yellow, the server is in the standby state.
–
Press the power button on the front panel to power on the server. For details about
the power button position, see
–
Power on the server using the iBMC WebUI. For details, see
–
Power on the server using the iBMC command-line interface (CLI) in remote
management mode.
Log in to the iBMC CLI. For details, see
9.3-Logging In to the iBMC CLI
Run the
ipmcset -d powerstate -v 1
command on the iBMC CLI to power on the
server remotely.
Procedure
Power on the server using the iBMC WebUI.
1.
Log in to the iBMC WebUI. For details, see
9.2 Logging In to the iBMC WebUI
.
2.
Choose
Power
>
Power Control
.
The
Power Control
page is displayed, as shown in
Figure 4-1
Power Control page
3.
Click
Power On
. In the displayed dialog box, click
Yes
to power on the server.
Verification
Check the indicator status after the server is powered on.
5288 V3 Server
User Guide
4 Powering On and Off the Server
Issue 26 (2018-11-19)