d.
Clear alarms. For details, see
HUAWEI Rack Server AlarmHandling (iBMC)
.
NOTE
indicates that no alarm is generated for the server, skip this step.
l
Check the 5288 V3 using the iBMC CLI.
a.
Log in to the iBMC CLI.
i.
Set an IP address for the PC, and ensure that the IP address is on the same
network segment as the iBMC management network port.
ii.
Connect the PC to the 5288 V3 iBMC management network port by using a
network cable.
iii. Run the Secure Shell (SSH) tool on the PC, and enter the IP address of the
iBMC management network port, user name, and password to log in.
NOTE
By default, SSH is used to log in to iBMC. If the SSH service is disabled, enable it by
choosing
Config
>
Service Settings
on the iBMC WebUI.
b.
View the 5288 V3 version information.
Check that the 5288 V3 versions meet site requirements.
iBMC / # ipmcget -d ver
------------------- iBMC INFO
-------------------
IPMC CPU:
Hi1710
IPMI Version:
2.0
CPLD Version:
(U46)1.05
Active iBMC Version:
(U25)1.62
Active iBMC Built: 22:00:15 Jun 12
2015
Backup iBMC Version:
1.59
SDK Version:
1.51
SDK Built: 17:00:37 May 17
2015
Active Uboot Version: 1.1.35 (Mar 25 2015 -
10:24:41)
Backup Uboot Version: 1.1.35 (Mar 25 2015 - 10:24:41)
----------------- Product INFO -----------------
Product ID: 0x0001
Product Name: 5288 V3
BIOS Version: (U47)1.36
-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x0002
Mainboard PCB: .C
------------------- Flexible NIC INFO -------------------
SM210 BoardID: 0x0014
SM210 PCB: .A
----------------Raid Card INFO -------------------
SR130 BoardID: 0x002C
SR130 PCB: .A
-------------- HDD Backplane INFO --------------
BC11THBK BoardID: 0x00cb
BC11THBK PCB: .A
BC11THBK CPLD Version: (U1011)1.05
BC11THBJ BoardID: 0x00ca
BC11THBJ PCB: .A
BC11THBJ CPLD Version: (U3)1.05
5288 V3 Server
User Guide
5 Configuring the 5288 V3
Issue 26 (2018-11-19)
Copyright © Huawei Technologies Co., Ltd.
98