![Huawei 3010 Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/huawei/3010/3010_troubleshooting-manual_169671099.webp)
Fault
Symptom
Handling Procedure
Quick Recovery Method
The POST
stops
respondin
g at a
screen.
1. Capture the current screen.
2. Collect iMana 200 or iBMC
logs, and query the CPLD
register to determine whether
the power supply link to the
mainboard has failed.
3. Set the printing level for
debugging the BIOS with the
iMana 200 or iBMC CLI.
NOTE
You can run the ipmcset -t
maintenance -d biosprint -v 1
command to print all BIOS logs.
For details, see "Querying and
Setting BIOS Print Enablement
Status (biosprint)" in the
of the required
version.
4. Enable the video recording
function on the iMana 200 or
iBMC WebUI, restart the
server, and save system serial
port logs. When the fault is
repeated, collect iMana 200 or
iBMC logs and download
the .bin file of the BIOS.
5. Check the external USB
devices, CPUs, drives, DIMMs,
and PCIe devices.
Huawei Servers
Troubleshooting
5 Diagnosing and Rectifying Faults
Issue 20 (2020-09-25)
Copyright © Huawei Technologies Co., Ltd.
90