Figure 8-14 Product SN
8.2 Using iMana 200 to Collect Information in Batches
This method applies only to servers and blades. To collect logs of switch modules
in batches, use the MM910 WebUI.
Procedure
Step 1 Use PuTTY to log in to the server. For details, see
Over a Network Port by Using PuTTY
8.17 Logging In to a Compute Node,
Passthrough Module, or Switch Module by Using the SOL Function of the
Step 2 On the iMana 200 CLI, run the imtool command (for versions earlier than 7.01) or
the ipmcset -t maintenance -d imtool command (for 7.01 and later versions).
Information similar to the following is displayed:
root@BMC:/#ipmcset -t maintenance -d imtool
tar: removing leading '/' from member names
Tar result information success.
iMana:/->
If the following information is displayed, log collection is successful.
tar: removing leading '/' from member names
Tar result information success.
Step 3 Use a cross-platform file transfer tool to connect to the iMana 200 IP address.
In this document, WinSCP is used as the cross-platform file transfer tool. For
8.19 Using WinSCP to Transfer Files
Step 4 Download the tar.gz package in the /tmp directory on iMana 200 to a directory on
the local PC. See
.
Figure 8-15 WinSCP window
Huawei Servers
Troubleshooting
8 Common Operations
Issue 20 (2020-09-25)