![Huawei 3010 Скачать руководство пользователя страница 78](http://html.mh-extra.com/html/huawei/3010/3010_troubleshooting-manual_169671078.webp)
Table 5-16 E9000 switch module indicators
Indicator
Status
Meaning
Diagnosis
Procedure
Stack status
indicator (STAT)
Steady green
A switch module
that can be
stacked is active
in stacking mode
or is not stacked,
and is operating
properly.
N/A
A switch module
that cannot be
stacked is
operating
properly.
Blinking green
A switch module
that can be
stacked is standby
or slave in
stacking mode
and is operating
properly.
A switch module
that cannot be
stacked is being
powered on.
Off
The switch
module is not
powered on.
Health indicator
(HLY)
Steady green
The switch
module is
operating
properly.
N/A
Blinking red
The switch
module has a
fault alarm or is
not installed
properly.
Log in to the
HMM WebUI to
view event
alarms, and check
whether the
switch module is
installed and
operating
properly.
Off
The switch
module is not
powered on.
N/A
Huawei Servers
Troubleshooting
5 Diagnosing and Rectifying Faults
Issue 20 (2020-09-25)
Copyright © Huawei Technologies Co., Ltd.
69