8
NOTE:
If the boiler is exposed to the following, do not operate until all corrective steps have been made by a
qualified serviceman:
1. FIRE
2. DAMAGE
3. WATER
Any claims for damage or shortage in shipment must be filed immediately against the transportation company by
the consignee.
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN SUBMERGED IN WATER.
Immediately call a
qualified service technician. The appliance MUST BE replaced if it has been submerged. Attempting to operate an
appliance that has been submerged could create numerous harmful conditions, such as a potential gas leakage
causing a fire and/or explosion, or the release of mold, bacteria, or other harmful particulates into the air.
Operating a previously submerged appliance could result in property damage, severe personal injury, or death.
NOTE:
Appliance damage due to flood or submersion is considered an Act of God, and IS NOT covered under
product warranty.
Be sure to disconnect electrical power before opening boiler cabinet or performing service. Failure to do so could
result in an electrical shock that could result in property damage, serious personal injury, or death.
Due to the low water content of the boiler, improper sizing of the boiler with regard to heating system load will
result in excessive cycling and accelerated component failure. HTP
DOES NOT
warrant failures caused by
improperly sized boiler applications.
DO NOT
oversize the boiler to the system. Modular boiler installations greatly
reduce the likelihood of boiler oversizing.
B. IMPROPER COMBUSTION
C. GAS
Should overheating or gas supply fail to shut off, do not turn off or disconnect electrical supply to the circulator.
Instead, shut off the gas supply at a location external to the appliance.
D. WHEN SERVICING THE BOILER
To avoid electric shock, disconnect electrical supply before performing maintenance.
To avoid severe burns, allow boiler to cool.
E. BOILER WATER
If you have an old system with cast iron radiators, thoroughly flush the system (without boiler connected)
to remove sediment. The high-efficiency heat exchanger can be damaged by build-up or corrosion due to
sediment. HTP recommends a suction strainer in this type of system.
Do not use petroleum-based cleaning or sealing compounds in boiler system. Gaskets and seals in the
system may be damaged, possibly resulting in substantial property damage.
Do not obstruct the flow of combustion and ventilating air. Adequate air must be provided for safe operation.
Failure to keep the vent and combustion air intake clear of ice, snow, or other debris could result in property
damage, serious personal injury, or death.
Содержание EL-110
Страница 15: ...15 Figure 3 ...
Страница 61: ...61 Figure 29 ...
Страница 62: ...62 Figure 30 ...
Страница 87: ...87 Figure 33 ...
Страница 88: ...88 Figure 34 ...
Страница 89: ...89 Figure 35 LP 293 A NOTE Parts listed on the following page ...
Страница 94: ...94 ...
Страница 95: ...95 ...
Страница 96: ...96 MAINTENANCE NOTES ...