3.5mm to 3.5mm Cables
6 feet
8 inches
Vol
Vol
Source
Zone
Talk
Source In
Power/Mute
DND
Source Input Panel
Remote Control
Connect emitter(s) to the Lync
and place in front of other
components that you want to
control from within each zone.
Allows you to control audio
components located near
the Lync system, even when
hidden inside of a cabinet or
closet.
IR Emitters
IR Receiving Eyes
DND
Po
w
er
So
urc
e
Vo
lume
M
ut
e
ZONE REMO
TE
+
_
Point at any LyncPad to select the source
and to control the volume level in that zone.
Sold Separately
For connecting an MP3 player, iPod®, etc. to 3.5mm input.
5-pin
green
connector
3.5mm
Stereo
Input
Double
IR-RX2
IR-TX2-M
IR-RX2-T
IR-RX2-IW
Single
*30 foot, 3-conductor cable included for connecting the Source Input Panel to the back of LyncPad. Adapters sold separately for using Cat5 in place of this cable.
*
Product Features
(cont.)
Connect a properly terminated Cat5 or Cat6 cable to either of the two RJ-45 ports on the back of the LyncPad. The “multi-
LyncPad terminator” (included with the LyncPad) can be plugged into the other RJ-45 port or left out. The “terminator” is
only REQUIRED when more than one LyncPad are connected to the same zone. For large zones, it is possible to daisy-
chain up to four LyncPads into the same zone. When doing this, you MUST insert the terminator in the last LyncPad in
order for the 3.5 mm inputs to work properly. Please note that a maximum of 12 LyncPads can be connected to a single
Lync 6 controller; a maximum of 24 LyncPads to the Lync 12.
When connecting more than one LyncPad into the SAME zone, each LyncPad must also have a unique combination of
shorting bars installed. Each LyncPad includes 2 shorting bars already installed- this represents one of the four possible
combinations. Removing only the left shorting bar is a second combination; removing only the right is a third; and removing
both shorting bars is a fourth combination. When more than one LyncPad is installed into the same zone, an adjustment
to any one LyncPad will automatically be “mirrored” by the other LyncPads.
Connecting the LyncPad
Vol
Vol
Source
Zone
Talk
Source In
Power/Mute
DND
Vol
Vol
Source
Zone
Talk
Source In
Power/Mute
DND
“Shorting Bars” -
only adjust if con-
necting more than
one LyncPad into
the same zone.
To Lync Controller
To Lync Controller
Daisy-chained LyncPads
Vol
Vol
Source
Zone
Talk
Source In
Power/Mute
DND
RJ45 multi-LyncPad “terminator” - only REQUIRED when con
-
necting more than one LyncPad into the same zone. However,
it is OKAY to install it in whichever RJ45 terminal is not being
used by the Cat5 or Cat6 cable connecting the LyncPad to the
Lync controller.
5