How to Connect
(CONT’D)
There is also an IR Input on the back of the Lync controller. This allows you to connect a receiving eye (sold separately) for
a room that does not have a LyncPad in it. This is often a nearby room such as a dedicated theater room or family room with
surround sound installed. IR commands received at this eye are ONLY output through the Global IR Output on the back
of the Lync. We provide a dual IR emitter for the Global IR Out so that you can control up to two devices with the separate
IR eye. Choose from three styles.
Every LyncPad has a built-in IR receiving eye. This IR eye is used to control the LyncPad from its remote control AND to
pass IR signals through the Lync controller to other centrally located equipment. The LyncPad’s basic functions- source
selection, volume up/down, power, mute, DND, and the MP3 functions- can all be controlled from the LyncPad’s own remote
control. But the IR eye on the LyncPad serves another very important function as well- it passes IR commands from the
standard 38K frequency band to the Lync and then on to your other centrally located equipment with the use of the included
IR emitters. In other words, you can control a centrally located device simply by pointing the IR remote control for that device
at any LyncPad.
Making use of Infrared (IR) Capability
Power
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
Zone Status
Source Signal Strength
AC 120V~60Hz
FUSE T2AL/250V
Power Consumption: 160W
ROUTED IR OUT
SOURCE INPUT
KEYP
AD PORT
S
7
8
9
10
11
12
MP3
L
ZONE 1 PREOUT
ZONE 2 PREOUT
ZONE 3 PREOUT
ZONE 4 PREOUT
ZONE 5 PREOUT
ZONE 6 PREOUT
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
R
L
4
3
2
1
5
6
IR IN
RS232
INTERFACE
GLOBAL
IR OUT
12V/DC
TRIGGER
100mA
IN
OUT
System
TRIGGER
AC/DC 3-20V
Mute
Made in Taiwan
CAUTION
To Prevent Electric Shock,
Do Not Remove Cover. No
User-Serviceable Parts Inside,
Refer Servicing To Qualified
Service Personnel.
WARNING
To Prevent Fire Or Shock
Hazard, Do Not Expose This
Unit To Rain Or Moisture.
FIXED
VA
RIABL
E
IR IN
Vol
Vol
Source
Zone
Talk
Source In
Power/Mute
DND
IR receiving eye located on
each LyncPad keypad
RJ45
RJ45
Lync
IR-RX2-T
IR-RX2
IR-RX2-IW
Power
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
Zone Status
Source Signal Strength
AC 120V~60Hz
FUSE T2AL/250V
Power Consumption: 160W
ROUTED IR OUT
SOURCE INPUT
KEYP
AD PORT
S
7
8
9
10
11
12
MP3
L
ZONE 1 PREOUT
ZONE 2 PREOUT
ZONE 3 PREOUT
ZONE 4 PREOUT
ZONE 5 PREOUT
ZONE 6 PREOUT
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
MONO
STEREO
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
R
L
4
3
2
1
5
6
IR IN
RS232
INTERFACE
GLOBAL
IR OUT
12V/DC
TRIGGER
DOOR
INTERFACE
100mA
IN
OUT
System
TRIGGER
AC/DC 3-20V
Mute
Made in Taiwan
CAUTION
To Prevent Electric Shock,
Do Not Remove Cover. No
User-Serviceable Parts Inside,
Refer Servicing To Qualified
Service Personnel.
WARNING
To Prevent Fire Or Shock
Hazard, Do Not Expose This
Unit To Rain Or Moisture.
FIXED
VA
RIABL
E
IR IN
Lync
Sold Separately
Sold Separately