Inspection and maintenance work
VK 5012
6.12
Adjusting the safety rip cord
Interval: daily
The safety rip cord is activated when the blue button (C) on the rip cord switch is
pushed in. The yellow button must come out when the rip cord is pulled.
If not, you must readjust the rip cord using the tensioning screw (D).