6.417.999.120
Installation
VK 5012
Issued 06/2005
5.26
- Turn on the main switch
- Perform strapping manually using the key-operated
“Bale ready”
switch once a
minimum bale length of approx. 400 mm is reached.
- Turn the
“Bale ready”
switch briefly to the right
• Display text: Bale length reached
- Press the
“Forward”
button.
• The press ram moves forwards and stops under pressure. The press ram lock
cylinders move forward and the wire insertion cylinders push the wire through the
channels of the press ram to the twisting unit. The twisting rods perform one rotation
and catch the wires. The shears in the twisting unit cut the wires, which are
immediately twisted. The wire insertion cylinders return to their initial position. The
press ram returns to its initial position and the twisting rods perform several
backward rotations to eject the wire ends.
- Release and remove the cut wire ends from the twisting and insertion side of the
press frame.