2 . E q u i p m e n t D e s i g n R e q u i r e m e n t s a n d C a u t i o n s
2.1 Receptacle Selection
The receptacle is available in both PCB and in-line types. Please select according to your usage.
<<PCB type>>
After tightening the screws to the board,
do reflow soldering.
Refer to the following for the board pattern.
For dimensions in( ), please apply dimensions of IEC60297-3, DIN41494 and IEEE1101 Euroboard
standards.
The figure shows 41pins pattern below. For 28pins, the portion framed in red(※dimensions)
is not required.
When used as a rated current of 4A, a land width that supports 4A is required.
However, there is a risk that the pattern of the adjacent contacts may interfere with each other.
Please do not place the multi-layer PCB or the contacts for 4A current flow adjacent to each
other.
<<In-line Type>>
The crimp contact connected to the cable can be inserted into the housing.
Crimp Contact
TJ50A-****PCA
Units: mm
unnecessary
for 28 pins