TITLE
:
TJA Series Guideline
ETAD-E3232-00
Rev No. 0
HIROSE ELECTRIC CO.,LTD.
OBJECT
PRODUCT
:
TJA Series
PAGE:
16
OF
25
<<In-line type>>
1. Insert the crimped male contact in the direction of the arrow until it reaches the inside of
the housing.The contact lance is on the side without the housing polarity mark (Δ).
2. Put the panel, spacer (when panel thickness is insufficient), shell, misinsertion prevention
key into the housing and secure with screws.
(Recommended tightening torque 0.36 ± 0.07 N·m)
Since the housing is structured to attach to the panel even when reversed by
180 degrees, install it to the panel in the intended direction, refering to the contact no.
position and the polarity mark.
Panels and spacers are not provided. Please purchase them from panel manufacturers.
Housing
Panel
Spacer
Shell
Misinsertion Prevention Key
Polarity Mark
Contact No.
(If the panel is not thick enough)
Side Without
Polarity Mark
Contact Lance
Side Without Polarity Mark
The lance of the contact is hooked and
secured at the projection of the housing.
Section A-A
Side With Polarity Mark
Aug.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.