TITLE
:
TJA Series Guideline
ETAD-E3232-00
Rev No. 0
HIROSE ELECTRIC CO.,LTD.
OBJECT
PRODUCT
:
TJA Series
PAGE:
11
OF
25
2.5 Plug Selection
The appropriate plug selection depends on the type of cable to be used and the cabling direction.
Please check the following and select the plug accordingly.
Metal Clamp
Upward Cabling
Downward Cabling
Standard
TJ50A-41S-U-CV
TJ50A-41S-D-CV
Cable Tie
TJ50A-41S-U-CV1
TJ50A-41S-D-CV1
<<Metal Clamp Design>>
CV Clamp metal : Fits inside the unit
CV1 Clamp metal : Protrudes from unit
Using cable ties can reduce cable shaking (see Section 3.4)
Since the unit is exposed to the outside, be careful not to interfere with
other products. The width of the CV is 79.3 mm and the width of CV1 is 93 mm.
When using a cabtire cable, we recommend CV1 which can be fixed at two points.
This is because it is difficult to bend the cable when it is moved, so the cable may rotate
around the center of the clamp if there is only one fixing point and apply a load to the
crimping part.
<<One Fixing Point on CV>> <<Two Fixing Points on CV1>>
Secured at Two Points with
Both Clamp and Cable Tie
Clamp Secures Cable
at One Point
If you move the cable,
the crimping part may move in
the opposite direction.
Even moving the cable,
the crimping part doesn’t move
due to cable tie.
Cabtire Cable
Standard Type
TJ50A-41S-U-CV
4.5
Metal Clamp
Type Secured by Cable Tie
TJ50A-41S-U-CV1
Metal Clamp
2.5
Aug.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.