TITLE
:
TJA Series Guideline
ETAD-E3232-00
Rev No. 0
HIROSE ELECTRIC CO.,LTD.
OBJECT
PRODUCT
:
TJA Series
PAGE:
12
OF
25
In addition, the metal clamp height differs from stated dimensions and the number of cables that
can be stored is different.
Refer to the table below. (It depends on the cable you use, so please check the actual product.)
Type of Clamp
Loose Line (φ3.2)
Cabtire Cable (φ9.6)
CV clamp
41 pins
-
CV1 clamp
31 pins
3
The tensile strength of the cable may be under 98 N depending on the diameter of the cable used,
the material and composition of the sheath, the number of pins, etc.
Therefore, adjust the cable diameter with a shrink tube or copper tape.
Example: When fixing 10 cables with a wire size of 26 AWG and outer diameter of insulator Φ1.3,
put the cable for use, cutting cables and other intervening materials into the shrink tube and
make the overall thickness Φ12.2 to 13.0.
<<Cable Direction>>
Depending on the plug, the cabling direction is either upward or downward.
One plug does not support both directions, so please be careful when choosing the connector.
(The VME standard determines the position of the contact number, so be careful when conforming
to the standard.)
Contact No.1
Contact No.1
Upward Cabling Type
TJ50A-41S-U-CV
Downward Cabling Type
TJ50A-41S-D-CV
Example:Place cable to be used and
cutting cables in a shrink tube.
Aug.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.