4.2 Contact Assembly Confirmation Method
You can use the pin-push inspection tool (TJ50A/IN-MD) and inspection table (TJ50A/INCR-MD)
to check the contact assembly of both the receptacle side (in-line type) and plug side.
<<Receptacle (In-line type)>>
1. Align the polarity mark of the receptacle which has crimp contacts inserted with
the hole of inspection table. Set as shown below.
(This inspection table can be used even after installed to the panel.)
2. Insert the tip of the inspection tool straight into the hole of the inspection table
as shown below. Unlike the plug side inspection (Ref. ATAD-E3065), the receptacle side
inspection allows insertion of the inspection tool tip in any direction.
(The inspection tool is used for both the plug side and the receptacle side.)
<<Plug>>
1. Set the inspection tool in the direction shown below for the plug or housing with crimp
contacts inserted. In this case, if the side with the polarity mark (No.1 contact side) is up,
point the positioning key up as well.
※If you turn it in the opposite direction, it is difficult to inspect thoroughly.
Polarity Mark
Hole
Housing
(Receptacle Side)
Inspection Table
TJ50A/INCR-MD
Pin-Push Inspection Tool
TJ50A/IN-MD
Housing
(Plug Side)
Plug
Positioning Key
Polarity Mark
Positioning Key
Pin-Push Inspection Tool
TJ50A/IN-MD
Aug.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.