Name Description
Range
【
factory setting
】
F13.12
Idling exciting current of motor 2
0.00
-
99.99A
【
dependent on
inverter model
】
F13.13
Reserved
F13.14
Reserved
F13.15
Reserved
F13.16
V/f curve selection of motor 2
0
-
4
【
0
】
0: Line.
1: Square curve.
2: 1.2 exponential curve.
3: 1.7 exponential curve.
4: User-defined curve.
F13.17
V/f frequency value F3 of motor 2
F13.19
-
F13.04
【
0.00Hz
】
F13.18
V/f voltage value V3 of motor 2
F13.20
-
F13.02
【
0V
】
F13.19
V/f frequency value F2 of motor 2
F13.21
-
F13.17
【
0.00Hz
】
F13.20
V/f voltage value V2 of motor 2
F13.22
-
F13.18
【
0V
】
F13.21
V/f frequency value F1 of motor 2
0.00
-
F13.19
【
0.00Hz
】
F13.22
V/f voltage value V1 of motor 2
0
-
F13.20
【
0V
】
F13.23
Torque boost of motor 2
0.0
-
30.0
【
2.0%
】
F13.24
Cut-off point used for manual torque boost of motor 2
0.0
-
50.0 (F13.04)
【
30.0%
】
F13.25
Slip compensation gain of motor 2
0.0
-
300.0
【
100.0%
】
F13.26
Slip compensation filter time of motor 2
0.01
-
10.00
【
0.10s
】
F13.27
Slip compensation limitation of motor 2
0.0
-
250.0
【
200.0%
】
F13.28
Compensation constant of motor 2
0.1
-
25.0
【
2.0s
】
F13.29
Reserved
F13.30
AVR (automatic voltage regulation) function of motor 2
0
-
2
【
1
】
F13.31
Oscillation-suppression mode of motor 2
0,1
【
0
】
F13.32
Oscillation-suppression coefficient of motor 2
0
-
200
【
50
】
F13.33
Reserved
F13.34
Reserved
F13.35
Speed control proportional gain 1 of motor 2
0.1
-
200.0
【
20.0
】
F13.36
Speed control integral time 1 of motor 2
0.00
-
10.00
【
0.20s
】
F13.37
Speed control proportional gain 2 of motor 2
0.1
-
200.0
【
20.0
】
F13.38
Speed control integral time 2 of motor 2
0.00
-
10.00
【
0.20s
】
F13.39
Speed-loop PI switching frequency 1 of motor 2
0.00
-
50.00
【
10.00Hz
】
F13.40
Speed-loop PI switching frequency 2 of motor 2
0.00
-
50.00
【
15.00Hz
】
F13.41
Speed-loop integral limitation of motor 2
0.0
-
200.0 (F13.03)
【
180.0%
】
F13.42
Speed-loop differential time of motor 2
0.00
-
1.00
【
0.00s
】
F13.43
Speed-loop output filter time of motor 2
0.000
-
1.000
【
0.020s
】
F13.44
Reserved
F13.45
Reserved
F13.46
Motor torque limitation when motor 2 is forward
0.0
-
200.0 (F13.03)
【
180.0%
】
F13.47
Motor torque limitation when motor 2 is reverse
F13.48
Recreated torque limitation when motor 2 is forward
F13.49
Recreated torque limitation when motor 2 is reverse
F13.50