Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd
―
124
―
HD20 Series Inverters User Manual
No.
Name
Range
Factory
Default
Unit
Modified
attributes
Setting
(decreases to DWELL
frequency setting and holds on
retention time of DWELL
frequency, then it will stop)
1: Coast to stop
2: Decelerate to stop with DC
braking
F02.14
DWELL frequency setting
at stop
0.00
-
upper limit
0.00Hz
0.01Hz
×
F02.15
Retention time of DWELL
frequency at stop
0.00
-
10.00s
0.00s
0.01s
×
F02.16
DC braking initial
frequency at stop
0.00
-
50.00Hz
0.50Hz
0.01Hz
×
F02.17
DC braking waiting time at
stop
0.00
-
10.00s
0.00s
0.01s
×
F02.18 DC braking time at stop
0.00
-
60.00s
0.50s
0.01s
×
F02.19 Jog control mode
0: The jog functions of start
and stop mode etc are invalid.
1: The jog functions of start
and stop mode etc are
enabled.
0
1
×
Group F03 Acceleration/Deceleration Parameters (refer to pages 59
F03.00 Reserved
F03.01 Acceleration time 1
0.01
-
600.00s
10.00s
0.01s
○
F03.02 Deceleration time 1
0.01
-
600.00s
10.00s
0.01s
○
F03.03 Acceleration time 2
0.01
-
600.00s
10.00s
0.01s
○
F03.04 Deceleration time 2
0.01
-
600.00s
10.00s
0.01s
○
F03.05 Acceleration time 3
0.01
-
600.00s
10.00s
0.01s
○
F03.06 Deceleration time 3
0.01
-
600.00s
10.00s
0.01s
○
F03.07 Acceleration time 4
0.01
-
600.00s
10.00s
0.01s
○
F03.08 Deceleration time 4
0.01
-
600.00s
10.00s
0.01s
○
F03.09
Switching frequency of
acceleration time 2 and
time 1
0.00
-
upper limit
0.00Hz
0.01Hz
×
F03.10
Switching frequency of
deceleration time 2 and
time 1
0.00
-
upper limit
0.00Hz
0.01Hz
×
F03.11 Reserved
F03.12 Reserved
F03.13 Reserved
F03.14 Reserved
F03.15
Acceleration time of jog
operation
0.01
-
600.00s
6.00s
0.01s
○
F03.16 Deceleration time of jog
0.01
-
600.00s
6.00s
0.01s
○