Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd
―
134
―
HD20 Series Inverters User Manual
No.
Name
Range
Factory
Default
Unit
Modified
attributes
Setting
motor 2
F13.26
Slip compensation filter
time of motor 2
0.01
-
10.00s
0.10s
0.01s
○
F13.27
Slip compensation
limitation of motor 2
0.0
-
250.0%
200.0%
0.1%
×
F13.28
Compensation constant of
motor 2
0.1
-
25.0s
2.0s
0.1s
○
F13.29 Reserved
F13.30 AVR function of motor 2
0: Disabled
1: Enabled all the time
2: Disabled in deceleration
process
1
1
○
F13.31
Oscillation-suppression
mode of motor 2
0: Oscillation suppression is
dependent on the motor’s
exciting current component
1: Oscillation suppression is
dependent on the motor’s
torque current component
0
1
○
F13.32
Oscillation-suppression
coefficient of motor 2
0
-
200
50
1
○
F13.33 Reserved
F13.34 Reserved
F13.35
Speed control proportional
gain 1 of motor 2
0.1
-
200.0
20.0
0.1
○
F13.36
Speed control integral time
1 of motor 2
0.00
-
10.00s
0.20s
0.01s
○
F13.37
Speed control proportional
gain 2 of motor 2
0.1
-
200.0
20.0
0.1
○
F13.38
Speed control integral time
2 of motor 2
0.00
-
10.00s
0.20s
0.01s
○
F13.39
Speed-loop PI switching
frequency 1 of motor 2
0.00
-
50.00Hz
10.00Hz
0.01Hz
○
F13.40
Speed-loop PI switching
frequency 2 of motor 2
0.00
-
50.00Hz
15.00Hz
0.01Hz
○
F13.41
Speed-loop integral
limitation of motor 2
0.0
-
200.0% (F13.03)
180.0%
0.1%
○
F13.42
Speed-loop differential
time of motor 2
0.00
-
1.00s
0.00: There is not the
speed-loop differential
0.00s
0.01s
○
F13.43
Speed-loop output filter
time of motor 2
0.000
-
1.000s
0.000:The speed-loop filter is
disabled
0.020s
0.001s
○
F13.44 Reserved
F13.45 Reserved
F13.46 Motor torque limitation
0.0
-
200.0% (F13.03)
180.0%
0.1%
×