• The appliance insertion is complete when the
Update Image Streamer activity completes successfully and the
Deployment Appliances screen displays information about two member appliances. Do not remove the inserted
appliance until this message is displayed.
• When the same appliance that was removed earlier is reinserted, the reinserted appliance undergoes a factory reset
and powers off. Then, you must click the Factory Reset link on the
SERVERS > Enclosures screen in HPE OneView
user interface.
NOTE: If the CIM is in the local ring, then Factory Reset link in the alert will power on automatically. If the CIM is in the
remote ring, you must manually power on the CIM and then click the Factory Reset link.
You might encounter GEC errors during the process. Follow the recommendations provided in the alert until it is
cleared. It might require you to refresh the enclosure and reinsert the appliance a few times. Once the GEC errors are
resolved, appliance configuration and clustering take
up to 1 hour to complete so that high availability is restored.