4.
Proceed to
Preparing the server for operation
on page 115.
Preparing the server for operation
Procedure
1.
Install any options or cables previously removed to access the TPM connector.
2.
Install the access panel.
3.
Do one of the following:
a.
Install the server in the rack, if necessary.
b.
Install the server in the enclosure.
4.
Power up the server.
a.
Connect the power cords (rack and tower servers).
b.
Press the Power On/Standby button.
Enabling the Trusted Platform Module
When enabling the Trusted Platform module, observe the following guidelines:
• By default, the Trusted Platform Module is enabled as TPM 2.0 when the server is powered on after
installing it.
• In UEFI Boot Mode, the Trusted Platform Module can be configured to operate as TPM 2.0 or TPM 1.2.
• In Legacy Boot Mode, the Trusted Platform Module configuration can be changed between TPM 1.2 and
TPM 2.0, but only TPM 1.2 operation is supported.
Enabling the Trusted Platform Module as TPM 2.0
Enabling the Trusted Platform Module
115