250
Chapter 5
Configuring ITO
Preconfigured Elements
❏
by inserting the marker into the text of a
TELLOP
command.
❏
by inserting the marker into a parameter for calling the
PRINTOP
command.
❏
by calling the
NMEVENT
intrinsic by way of a program.
The NMEV marker string can be placed in
TELLOP
messages. This can
be useful for generating messages to ITO from within jobs or sessions.
The
PRINTOP
intrinsic can also be used to send the NMEV marker to the
console from programs. In both cases, the MPE/iX Console Interceptor
processes the message. In all cases, the valid NMEV marker is stripped
from the text of the message before the messages is forwarded to the
message browser.
The NMEVENT intrinsic performs a function similar to
opcmsg(3)
.
Some networking and other third-party applications may use this
intrinsic but it is recommended that all applications that generate ITO
events use the
opcmsg(3)
call instead of the NMEVENT API.
New NMEV markers may be added to the
consdesc
file so that ITO can
map user-defined NMEV markers to user-defined ITO message groups,
application and object fields. It is not recommended to create
user-defined IDs because it is possible that the user-defined application
IDs could conflict with HP-defined ID in the future, if HP added entries
to the default
consdesc file
. The default
consdesc
file is located in
the following directory on the management server:
/var/opt/OV/share/databases/OpC/mgd_node/vendor/hp/s900\
/mpe-ix/<
ito_version
>/cmds/consdesc.Z
This file is compressed and must be uncompressed before you can start
editing it. Place your customized version of this file into the following
directory on the management server, and distribute it using the
Install / Update ITO Software and Configuration
window.
You do not need to compress it; ITO does that for you.
/var/opt/OV/share/databases/OpC/mgd_node/customer/hp\
/s900/mpe-ix/cmds/consdesc
After the distribution the file is located at
CONSDESC.COMMANDS.OVOPC
on the MPE/iX managed node.
NOTE
You must restart the MPE/iX console interceptor on your MPE/iX
managed node to activate the changes in the file
CONSDESC.COMMANDS.OVOPC
:
Содержание -UX B6941-90001
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 27: ...27 1 Prerequisites for Installing ITO Agent Software ...
Страница 43: ...43 2 Installing ITO Agents on the Managed Nodes ...
Страница 115: ...115 3 File Tree Layouts on the Managed Node Platforms ...
Страница 162: ...162 Chapter3 File Tree Layouts on the Managed Node Platforms File Tree Layout on Windows NT Managed Nodes ...
Страница 163: ...163 4 Software Maintenance on Managed Nodes ...
Страница 183: ...183 5 Configuring ITO ...
Страница 298: ...298 Chapter5 Configuring ITO Variables ...
Страница 299: ...299 6 Installing Updating the ITO Configuration on the Managed Nodes ...
Страница 315: ...315 7 Integrating Applications into ITO ...
Страница 333: ...333 8 ITO Language Support ...
Страница 352: ...352 Chapter8 ITO Language Support Flexible Management in a Japanese Environment ...
Страница 353: ...353 9 An Overview of ITO Processes ...
Страница 372: ...372 Chapter9 An Overview of ITO Processes Secure Networking ...
Страница 373: ...373 10 Tuning Troubleshooting Security and Maintenance ...
Страница 481: ...481 A ITO Managed Node APIs and Libraries ...
Страница 499: ...499 B Administration of MC ServiceGuard ...
Страница 512: ...512 AppendixB Administration of MC ServiceGuard Troubleshooting ITO in a ServiceGuard Environment ...
Страница 513: ...513 C ITO Tables and Tablespaces in the Database ...
Страница 520: ...520 AppendixC ITO Tables and Tablespaces in the Database ITO Tables and Tablespace ...
Страница 521: ...521 D ITO Man Pages Listing ...