![HP -UX B6941-90001 Скачать руководство пользователя страница 84](http://html.mh-extra.com/html/hp/ux-b6941-90001/ux-b6941-90001_administrators-reference-manual_164886084.webp)
84
Chapter 2
Installing ITO Agents on the Managed Nodes
General Installation Tips for Managed Nodes
also checked to make sure that it is running. If it isn’t, all
standard locations are checked for the
load xconsole
command. The configuration file of the primary IO Engine is
not searched.
• Checks for NetWare Management Agent (NMA)
The NMA agent is supported by the ITO agent for NetWare
server but this functionality requires NMA to be installed on
the selected NetWare servers; currently NMA installation is
not provided as part of the ITO agent for NetWare server
installation
• Checks for CLIB
The
CLIB.NLM
version is checked; version 4.10 or higher is
supported.
• Checks the disk space
• Checks the memory
The installation procedure knows how much memory in KB is
needed; this figure is subtracted from the NetWare server
parameter cache buffers. If the calculated amount is more than
30% of NetWare parameter total server work memory the
installation proceeds, otherwise the installation for the current
NetWare server is aborted, and the next selected NetWare
server is processed.
• Copies files
If the source file is a
.NLM
file, the installation checks if
.NLM
already exists on the target NetWare system. If it does, the
NetWare depot server is checked to see what version is
available there. Later versions of
.NLM
are always copied from
the NetWare depot server to the target. Older versions of
.NLM
are only copied to the target if you agreed to overwrite the
.NLM
. It is recommended to use the default option, that is; not
to overwrite previous versions.
• Flags directories as ‘purgable’
Deleted files occupy space although Novell NetWare can re-use
the space in a low disk quota situation. Deleted files can be
completely removed with the command-line utility
PURGE
. If a
directory is marked ‘purgable’ then each deleted file is no
longer kept by Novell.
Содержание -UX B6941-90001
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 27: ...27 1 Prerequisites for Installing ITO Agent Software ...
Страница 43: ...43 2 Installing ITO Agents on the Managed Nodes ...
Страница 115: ...115 3 File Tree Layouts on the Managed Node Platforms ...
Страница 162: ...162 Chapter3 File Tree Layouts on the Managed Node Platforms File Tree Layout on Windows NT Managed Nodes ...
Страница 163: ...163 4 Software Maintenance on Managed Nodes ...
Страница 183: ...183 5 Configuring ITO ...
Страница 298: ...298 Chapter5 Configuring ITO Variables ...
Страница 299: ...299 6 Installing Updating the ITO Configuration on the Managed Nodes ...
Страница 315: ...315 7 Integrating Applications into ITO ...
Страница 333: ...333 8 ITO Language Support ...
Страница 352: ...352 Chapter8 ITO Language Support Flexible Management in a Japanese Environment ...
Страница 353: ...353 9 An Overview of ITO Processes ...
Страница 372: ...372 Chapter9 An Overview of ITO Processes Secure Networking ...
Страница 373: ...373 10 Tuning Troubleshooting Security and Maintenance ...
Страница 481: ...481 A ITO Managed Node APIs and Libraries ...
Страница 499: ...499 B Administration of MC ServiceGuard ...
Страница 512: ...512 AppendixB Administration of MC ServiceGuard Troubleshooting ITO in a ServiceGuard Environment ...
Страница 513: ...513 C ITO Tables and Tablespaces in the Database ...
Страница 520: ...520 AppendixC ITO Tables and Tablespaces in the Database ITO Tables and Tablespace ...
Страница 521: ...521 D ITO Man Pages Listing ...