TCP/IP Subagent
SNMP Configuration and Management Manual — 424777-006
8 -100
1013: ZTSA-EVT-CONFIGURATION-INVALID
ZEMS-VAL-INTERNAL-FAILED
indicates that an internal error was encountered. The DDL AS clause associated
with this value (“internal-failed”) is inserted in the message text following “cause.”
ZTSA-VAL-STATE-ENABLED
indicates the previous state of the TCP/IP Subagent process. The DDL AS clause
of this value (“enabled”) appears in the message text following “previous state.”
ZTSA-VAL-STATE-DISCONNECTED
indicates the current state of the TCP/IP Subagent process. The DDL AS clause of
this value (“disconnected”) appears in the message text following “current state.”
configuration-fault-detail
provides additional information about the configuration in the following format:
Agent process name parameter bad-value invalid
TCP/IP process name parameter bad-value invalid
Non-local TCP/IP process name parameter bad-value
Collector process name parameter bad-value invalid
Info cache value bad-value, out of range
Stats cache value bad-value, out of range
Status cache value bad-value, out of range
Keep alive timer value bad-value, out of range
Backup CPU value bad-value, out of range
SCP process name parameter bad-value invalid
Non-local SCP process name parameter bad-value
Unrecognized parameter type bad-value
Incomplete parameter specification bad-value, missing
value
Parameter bad-value, specified multiple times
ZEMS-VAL-NULL
indicates the type of subsystem defined event. Because the TCP/IP Subagent
process has not defined this as a private event, the DDL AS clause “undefined”
always appears in the message text following “user content.”
Cause.
The startup parameters passed to the subagent process contain invalid
definitions or the specified agent process was not found.
Effect.
The TCP/IP Subagent terminates.
Recovery.
Check the startup parameter string passed to subagent. Check the
operating state of the specified SNMP agent process to ensure that it is running and
ready to accept subagent connections.
Note.
Event 1013 is sent to the EMS collector that is in effect when the parsing error is
detected. If the -c startup parameter is specified later in the startup string, after the error is
detected, the event is sent to the default collector $0. If $0 is not available, no event is
generated.
Содержание T9576G06
Страница 24: ...Contents SNMP Configuration and Management Manual 424777 006 xxii Tables continued ...
Страница 36: ...About This Manual SNMP Configuration and Management Manual 424777 006 xxxiv Change Bar Notation ...
Страница 38: ...Part I Installing and Configuring SNMP SNMP Configuration and Management Manual 424777 006 ...
Страница 140: ...Part II SCF for the SNMP Agent SNMP Configuration and Management Manual 424777 006 ...
Страница 208: ...Part III Troubleshooting SNMP Configuration and Management Manual 424777 006 ...
Страница 230: ...Part IV SNMP Subagents SNMP Configuration and Management Manual 424777 006 ...
Страница 340: ...TCP IP Subagent SNMP Configuration and Management Manual 424777 006 8 110 Converting Events to Traps ...
Страница 562: ...Trap Multiplexer Subagent Manager SNMP Configuration and Management Manual 424777 006 12 70 Application Source Code ...
Страница 636: ...IPX SPX Subagent G Series SNMP Configuration and Management Manual 424777 006 13 74 1012 ZISA EVT PROCESS TRAPPED ...
Страница 704: ...Part V Appendices SNMP Configuration and Management Manual 424777 006 ...
Страница 778: ...Index SNMP Configuration and Management Manual 424777 006 Index 32 Special Characters ...