Event
Number
(dec/hex)
Event
Name
Logged?
Predictive
Maintenance
Implication
Suspected
Components
Mf
g Fail?
Description
parameters stored there will probably revert to their
default values.
122/0x7a
Hardware error prevents
successful command
completion
Y
None of these are
allowed
Unknown
Y
The command failed because a required access to
hardware failed and was either not retried or was
retried unsuccessfully.
123/0x7b
Host Port Behavior Table
overflow
Y
None of these are
allowed
Unknown
Y
An attempt was made to add a new entry to the host
port behavior table but no unused entry was
available. An existing entry must be deleted to
make room for the new entry.
124/0x7c
Sequencer error injection error
N
These only occur
in internal testing
Unknown
Y
This error is used for a variety of purposes when
injecting errors in sequencer module tests.
125/0x7d
Test mode is required for this
command
N
These only occur
in internal testing
Unknown
Y
The command that was received is only allowed
when the test mode flag in the personality is true.
126/0x7e
Subsystem LUN configuration
changed UA
N
Ignore
None
N
This error is used to report a Unit Attention for LUN
Inventory changed.
127/0x7f
Mode parameters were restored
from defaults UA
N
Ignore
None
N
This error is used to report a Unit Attention for the
case where mode parameters were restored from
defaults.
128/0x80
Limit to supported number of
Principals has been reached
Y
Ignore - Remove
unwanted
associations from
Security map
None
Y
The LUN Security Utility cannot add any more
associations for new Principals because the
supported limit for Principals has been reached.
129/0x81
Disk Interface Error - no
logging
N
N.A.
None
N
A command to a backend device failed in an
expected manner, so that logging is not required.
130/0x82
Disk Interface Error
Y
N.A.
None
N
A command to a backend device failed with sense
data indicating an unexpected error.
131/0x83
Disk Interface Command
Failed
Y
N.A.
None
N
A command to a backend device failed due to an
error that does not include sense data from the
device.
132/0x84
Host is not authorized to access
LUN
Y
Ignore - Host
doesn’t have
permission to
access LUN
None
Y
LUN Security Authoriztion failed - Host attempted
to perform an operation on a LUN without having
an appropriate access permission.
133/0x85
Cannot identify a FRU in
phatom enclosure with id 0xff
Y
Ignore - Cannot
identify FRU in
phantom
enclosure
None
N
Phantom enclosure is a collection of disks with no
physical slot mapping. Ideally there should not be
any disk in phatom enclosure
134/0x86
Journal Manager Buffer Write
Failed
Y N.A. Journal
Manager
Y
A Journal Manager Buffer Write has failed.
Resilient map updates have not been posted to disk.
FUA write failures may result from this condition
135/0x87
Journal Manager Stage Write
Failed
Y N.A. Journal
Manager
Y
A Journal Manager Stage Write has failed. Resilient
map updates have not been posted to disk. FUA
write failures may result from this condition
Event
Event E
v
e
nt
Predictive Suspected
M
fg
Description
Number
Name L
o
g
g
e
d
?
Maintenance Components F
ai
l?
(dec/hex)
Implication
256/0x100
Access Time Count Error
Y
Ignore.
None
N
The frequency distribution table used to locate
recently modified blocks was found to be
inconsistent. This is indicative of a firmware
problem. This problem is self correcting.
257/0x101
Disk Drive Placed In Failed
State
Y Single
Occurrance
Disk Drive,
Controller,
Back End FC
Link
N
The firmware made a decision to automatically fail
a disk device due to its accumulated error history.
258/0x102
NVRAM Image Out Of Date
Y
Ignore - Operator
activity
None
N
During startup a disk stamp newer than the
NVRAM committed stamp copy was found. This
indicates the volume set attached successfully to a
different controller and this VS related NVRAM is
not valid.
259/0x103
No Quorum For Disk Set
Access
Y
Ignore - Operator
activity or
None
N
During startup a quorum of the drives belonging to
the volume set the NVRAM stamp were not present.